NF C61-314法國(guó)插頭插座量規(guī)一覽表
2015/9/16 21:05:06 點(diǎn)擊:
| 序號(hào) |
圖號(hào) |
描述 |
| 1 |
NFC613-14/C1 |
Pour verifier l’impossibilite de l’introduction d’une seule broche des fiches |
| 2 |
NFC613-14/C2 |
Pour verifier les dimensions des orifices d’entree des broches des fiches |
| 3 |
NFC613-14/C3A. B.C |
Pour verifier la distance jusqu’an preminer point de contact |
| 4 |
|
16A (5.45/5.6/5.75) |
| 5 |
NFC613-14/C4A |
Pour verifier la force minimale d’extraction |
| 6 |
|
6A (3.94/150g) |
| 7 |
NFC613-14/C4B |
16A (3.8/400g) |
| 8 |
|
16A (3.8/200g) |
| 9 |
NFC613-14/C4C |
16A (4.6/400g) |
| 10 |
|
16A (4.6/200g) |
| 11 |
NFC613-14/C5 |
Pour verifier l’introduction des fiches bipolaires 16A |
| 13 |
NFC613-14/C6 |
Pour verifier l’ouverture maximale de l’alveole de la feuille de norme v |
| 14 |
NFC613-14/C7A. B |
Pour verifier l’entraxe des broches 16A |
| 序號(hào) |
圖號(hào) |
描述 |
| 1 |
SE 1 |
10/16A 250V two-pole socket-outlets SE 1 for size of entry holes for plug pins |
| 2 |
SE 2 |
10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact SE 2 for minimum opening of contact tubes |
| 3 |
SE 3 |
10/16A 250V two-pole socket-outlets Gauge c3 for acceptance of two-pole plugs |
| 4 |
SE 4 |
10/16A 250V two-pole socket-outlets with side earthing-contacts SE 4 for acceptance of two-pole plugs with side earthing contacts |
| 5 |
SE 6A.B |
10/16A 250V two-pole fixed socket-outlets SE 6 for fixing holes or slots |
| 6 |
SE 7A.B.C.D |
10/16A 250V two-pole socket-outlets Gauges c7 for distance to point of first contact |
| 7 |
SE 8 |
10/16A 250V two-pole socket-outlets SE 8 for wiring channel |
| 8 |
SE 9A.B |
2.5A 250V and 10/16A250V two-pole plugs and 10/16A 250V two-pole socket-outlets with pin-type earthing-contact SE 9 for pin diameter |
| 9 |
SE 10A.B |
10/16A 250Vtwo-pole plugs SE 10 for pin spacing |
| 10 |
SE 11 |
10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact SE 11 for maximum opening of contact tubes |
| 11 |
SE 12 |
10/16A 250V two-pole plugs with side earthing-contacts SE 12 for interchangeability |
| 12 |
SE 13 |
2.5A 250V two-pole plugs for class ii appliances Gauge for interchangeability |
| 13 |
SE 15 |
10/16A 250V two-pole plugs without earthing contact Gauge for non-interchangeability with two-pole plugs with earthing contact |
| 14 |
SE 16 |
10/16A 250V two-pole socket-outlets with side earthing-contacts Gauge for non-acceptance of two-pole plugs without earthing contact |
| 15 |
SE 18 |
10/16A 250V two-pole socket-outlets without earthing contact Gauge for checking impossibility of single-pole insertion of plugs |
| 16 |
SE 19A.B |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
| 17 |
SE 19a |
2.5A 250V and 10/16A 250V two-pole plugs Gauges for checking impossibility of single-pole insertion of plugs into socket-outlets |
| 18 |
SE 21 |
Device for checking the resistance to lateral strain of 10/16A 250V two-pole fixed socket-outlets |
| 19 |
SE 23 |
Device for measuring the contact pressure of earthing contacts of 10/16A 250V two-pole socket-outlets with side earthing-contacts |
| 20 |
SE 24 |
Apparatus for breaking capacity and normal operation tests |
| 21 |
SE 25 |
Circuit diagrams for breaking capacity and normal operation tests |
| 22 |
SE 26 |
Apparatus for checking the withdrawal force |
| 23 |
IEC 60884-Fig9 |
Gauge for checking non-accessibility of live parts, through shutters |
24 |
IEC 60884-Fig10
|
Gauge for checking non-accessibility of live parts, through shutters and of live parts of socket-outlets with increased protection
|